banner koha

Performance of solar radiation models for obtaining reference evapotranspiration to Santa Maria-RS, Brazil

Por: Tipo de material: ArtigoArtigoAssunto(s): Recursos online: Em: Revista Brasileira de Ciências Agrárias (Brazil) v. 15(1) p. 1-8; (2020)Sumário: ABSTRACT: In the absence of observed data from Solar radiation (Sr), it is possible to estimate it using mathematical models. In general, the models vary in degree of complexity and the adjustment coefficients, and these must be calibrated to the place of interest to obtain the best performance. In this regard, the present work aims to evaluate the performance of simplified models of solar radiation in obtaining reference evapotranspiration. The data were obtained from the automatic meteorological station of the National Meteorological Institute (Inmet), located in Santa Maria – RS, Brazil. In the estimates of global solar radiation and its influence on reference evapotranspiration, ten models were evaluated, five models with the coefficients calibrated and five models, with the coefficients determined by the authors. It was observed that all the models studied presented performance index above 0.82, indicating “optimal” performance. Thus, both calibration and non-calibration models to obtain Sr do not interfere with ETo estimation. Therefore, given the impossibility of obtaining Sr data in meteorological stations, it is possible to use any of the models analyzed. Key words: air temperature; evaporative demand; Penman-Monteith; water requirementSumário: RESUMO: Na ausência de dados observados de Radiação Solar (Rs) é possível estimá-la mediante a utilização de modelos matemáticos. Em geral, os modelos variam em grau de complexidade e nos coeficientes de ajuste, e esses devem ser calibrados para o local de interesse para obtenção do melhor desempenho. Neste sentido, o presente trabalho tem como finalidade avaliar o desempenho de modelos simplificados de radiação solar na obtenção da evapotranspiração de referência. Os dados foram adquiridos junto a estação meteorológica automática do Instituto Nacional de Meteorologia (Inmet), localizada na cidade de Santa Maria – RS. Nas estimativas de radiação solar global e sua influência na evapotranspiração de referência, foram avaliados dez modelos, sendo cinco modelos com os coeficientes calibrados e cinco modelos, com os coeficientes determinados pelos autores. Observou-se que, todos os modelos estudados, apresentaram índice de desempenho acima de 0,82, indicando “ótimo” desempenho. Dessa forma, tanto os modelos com calibração quanto os sem calibração para a obtenção da Rs, não interferem na estimativa da ETo. Sendo assim, dada a impossibilidade de se obter os dados de Rs nas estações meteorológicas, é possível utilizar qualquer um dos modelos analisados. Palavras-chave: temperatura do ar; demanda evaporativa; Penman-Monteith; necessidade hídrica
Classificação por estrelas
    Avaliação média: 0.0 (0 votos)
Exemplares
Tipo de material Biblioteca atual Coleção Número de chamada Informaçaõ do volume URL Situação Devolução em Código de barras
Periódicos Periódicos Biblioteca Nacional de Agricultura - Binagri Agrobase - Periódicos Periódicos agrícolas 2020 15(1) Texto integral (PDF) Online 2026-1686



Publicação online; 46 ref.; 6 tables; 2 illus.; Summaries (En, Pt)




ABSTRACT: In the absence of observed data from Solar radiation (Sr), it is possible to estimate it using mathematical models. In general, the models vary in degree of complexity and the adjustment coefficients, and these must be calibrated to the place of interest to obtain the best performance. In this regard, the present work aims to evaluate the performance of simplified models of solar radiation in obtaining reference evapotranspiration. The data were obtained from the automatic meteorological station of the National Meteorological Institute (Inmet), located in Santa Maria – RS, Brazil. In the estimates of global solar radiation and its influence on reference evapotranspiration, ten models were evaluated, five models with the coefficients calibrated and five models, with the coefficients determined by the authors. It was observed that all the models studied presented performance index above 0.82, indicating “optimal” performance. Thus, both calibration and non-calibration models to obtain Sr do not interfere with ETo estimation. Therefore, given the impossibility of obtaining Sr data in meteorological stations, it is possible to use any of the models analyzed.



Key words: air temperature; evaporative demand; Penman-Monteith; water requirement




RESUMO: Na ausência de dados observados de Radiação Solar (Rs) é possível estimá-la mediante a utilização de modelos matemáticos. Em geral, os modelos variam em grau de complexidade e nos coeficientes de ajuste, e esses devem ser calibrados para o local de interesse para obtenção do melhor desempenho. Neste sentido, o presente trabalho tem como finalidade avaliar o desempenho de modelos simplificados de radiação solar na obtenção da evapotranspiração de referência. Os dados foram adquiridos junto a estação meteorológica automática do Instituto Nacional de Meteorologia (Inmet), localizada na cidade de Santa Maria – RS. Nas estimativas de radiação solar global e sua influência na evapotranspiração de referência, foram avaliados dez modelos, sendo cinco modelos com os coeficientes calibrados e cinco modelos, com os coeficientes determinados pelos autores. Observou-se que, todos os modelos estudados, apresentaram índice de desempenho acima de 0,82, indicando “ótimo” desempenho. Dessa forma, tanto os modelos com calibração quanto os sem calibração para a obtenção da Rs, não interferem na estimativa da ETo. Sendo assim, dada a impossibilidade de se obter os dados de Rs nas estações meteorológicas, é possível utilizar qualquer um dos modelos analisados.



Palavras-chave: temperatura do ar; demanda evaporativa; Penman-Monteith; necessidade hídrica

BINAGRI

Telefone: (61)3218-2567/2388/3357/2097 - binagri@agro.gov.br

Ministério da Agricultura e Pecuária , Esplanada dos Ministérios, Bloco D, Anexo B, Brasília/DF, CEP: 70.043-900