Spectrum of spray droplets with different nozzles and adjuvants
Tipo de material:
ArtigoAssunto(s): Recursos online:
Em: Revista Brasileira de Ciências Agrárias (Brazil) v. 15(2) p. 1-6; (2020)Sumário:
ABSTRACT: Successful application of agrochemicals depends on factors such as the droplet size, nozzle type and solution composition. In this context, the objective of this study was to evaluate the spectrum of spray droplets with different spray nozzles by means of direct measurement. The experiment was conducted in a completely randomized design, with a factorial scheme 2 x 4 x 2 + 2 (nozzles x adjuvants x concentrations + controls), with four replicates. Used nozzles were the CVI 11002 and TVI 800075, the adjuvants were the Break-Thru®, Haiten®, Iharaguen-S® and Orix® additives added to the solution at the concentrations of 100 and 150%, and the control, without adjuvant. A particulate analyzer was used to obtain the droplet spectrum. The diameter of the volumetric median, diameter of the numerical median, relative amplitude and percentage of the volume of droplets smaller than 100 μm. The spray nozzle CVI 11002 presented the diameter of the favorable volumetric median for the solutions application and safety against drift and a more homogeneous droplet spectrum. The Break-Thru® adjuvant had lower risk of drift, and the increased concentration of Orix® adjuvant increased the homogeneity of the droplet spectrum.
Key words: application technology; image analysis; real droplet sizeSumário:
RESUMO: O êxito na aplicação de produtos fitossanitários depende de fatores como tamanho de gota, tipo de ponta e composição da calda. Nesse contexto, objetivou-se avaliar a interferência de adjuvantes, adicionados a calda de pulverização, no desempenho das pontas quanto às características de espectro de gotas gerado por meio de medição direta. O experimento foi conduzido em delineamento inteiramente ao acaso, com esquema fatorial 2 x 4 x 2 + 2 (pontas x adjuvantes x concentrações dos adjuvantes + testemunhas), com quatro repetições. Foram utilizados as pontas CVI 11002 e TVI 800075, os adjuvantes Break-Thru®, Haiten®, Iharaguen-S® e Orix® adicionados à calda nas concentrações de 100 e 150%, e a testemunha, sem adjuvante. Para a obtenção do espectro de gotas foi utilizado um analisador de partículas por imagens. Foram avaliados o diâmetro da mediana volumétrica, diâmetro da mediana numérica, amplitude relativa e percentagem do volume de gotas menores de 100 μm. A ponta de pulverização CVI 11002 apresentou o diâmetro da mediana volumétrica favorável para a aplicação das caldas e segurança contra deriva e espectro de gotas mais homogêneo. O adjuvante Break-Thru® apresentou menor risco à deriva e o aumento da concentração do adjuvante Orix® elevou a homogeneidade do espectro das gotas.
Palavras-chave: tecnologia de aplicação; análise de imagens; tamanho real de gotas
| Tipo de material | Biblioteca atual | Coleção | Número de chamada | Informaçaõ do volume | URL | Situação | Devolução em | Código de barras |
|---|---|---|---|---|---|---|---|---|
Periódicos
|
Biblioteca Nacional de Agricultura - Binagri | Periódicos agrícolas | 2020 v. 15(2) | Texto integral (PDF) | Consulta local | 2026-1730 |
Publicação online; 32 ref.; 6 tables; Summaries (En, Pt)
ABSTRACT: Successful application of agrochemicals depends on factors such as the droplet size, nozzle type and solution composition. In this context, the objective of this study was to evaluate the spectrum of spray droplets with different spray nozzles by means of direct measurement. The experiment was conducted in a completely randomized design, with a factorial scheme 2 x 4 x 2 + 2 (nozzles x adjuvants x concentrations + controls), with four replicates. Used nozzles were the CVI 11002 and TVI 800075, the adjuvants were the Break-Thru®, Haiten®, Iharaguen-S® and Orix® additives added to the solution at the concentrations of 100 and 150%, and the control, without adjuvant. A particulate analyzer was used to obtain the droplet spectrum. The diameter of the volumetric median, diameter of the numerical median, relative amplitude and percentage of the volume of droplets smaller than 100 μm. The spray nozzle CVI 11002 presented the diameter of the favorable volumetric median for the solutions application and safety against drift and a more homogeneous droplet spectrum. The Break-Thru® adjuvant had lower risk of drift, and the increased concentration of Orix® adjuvant increased the homogeneity of the droplet spectrum.
Key words: application technology; image analysis; real droplet size
RESUMO: O êxito na aplicação de produtos fitossanitários depende de fatores como tamanho de gota, tipo de ponta e composição da calda. Nesse contexto, objetivou-se avaliar a interferência de adjuvantes, adicionados a calda de pulverização, no desempenho das pontas quanto às características de espectro de gotas gerado por meio de medição direta. O experimento foi conduzido em delineamento inteiramente ao acaso, com esquema fatorial 2 x 4 x 2 + 2 (pontas x adjuvantes x concentrações dos adjuvantes + testemunhas), com quatro repetições. Foram utilizados as pontas CVI 11002 e TVI 800075, os adjuvantes Break-Thru®, Haiten®, Iharaguen-S® e Orix® adicionados à calda nas concentrações de 100 e 150%, e a testemunha, sem adjuvante. Para a obtenção do espectro de gotas foi utilizado um analisador de partículas por imagens. Foram avaliados o diâmetro da mediana volumétrica, diâmetro da mediana numérica, amplitude relativa e percentagem do volume de gotas menores de 100 μm. A ponta de pulverização CVI 11002 apresentou o diâmetro da mediana volumétrica favorável para a aplicação das caldas e segurança contra deriva e espectro de gotas mais homogêneo. O adjuvante Break-Thru® apresentou menor risco à deriva e o aumento da concentração do adjuvante Orix® elevou a homogeneidade do espectro das gotas.
Palavras-chave: tecnologia de aplicação; análise de imagens; tamanho real de gotas

Periódicos
BINAGRI