245 _aSistema de lavagem de carcaças e controle de Salmonella spp. em abatedouros de frangos de corte
500 _a Publicação online; 29 ref.; 3 tables; Summaries (En, Pt)
520 _a RESUMO - Avaliaram-se os dados do controle e monitoramento de Salmonella em carcaças de frangos de corte, antes e após a implantação do sistema de lavagem de carcaças. Foram amostradas 2692 carcaças antes da instalação do sistema e 1940 após a instalação, totalizando 4632 amostras em cinco abatedouros sob Inspeção Federal, no sul do Brasil. Anteriormente à instalação dos lavadores, obtiveram-se 156 resultados positivos para Salmonella spp. e, após a instalação, 83 resultados positivos, com diferença significativa (P<0,05/OR 1,4) entre os resultados gerais. Em dois dos cinco abatedouros avaliados, houve redução na positividade para Salmonella spp. nas carcaças amostradas após a instalação do lavador. Entretanto, em três estabelecimentos não houve diferença significativa após a instalação desse sistema. Os resultados sugerem que o aumento da vazão da água está relacionado com a redução da contaminação, enquanto o aumento da pressão de água do sistema de lavagem não foi suficiente para reduzir o patógeno nas carcaças amostradas. Dessa forma, conclui-se que o sistema de lavagem tem vantagens do ponto de vista operacional, ao evitar os desperdícios atribuídos à prática do refile, porém não elimina o risco da presença de Salmonella na carcaça de frango. Palavras-chave: contaminação cruzada, controle, monitoramento, Salmonell
520 _a ABSTRACT - Data of the Control and Monitoring of Salmonella in broiler carcasses were evaluated before and afterthe implementation of a carcass washing system. A total of 2692 carcasses prior to system installation and 1940 after installation were sampled, totaling 4632 samples in five slaughterhouses under Federal Inspection in southern Brazil. Prior to installation of the washers, 156 carcasses were positive for Salmonella spp. and after installation, 83 carcasses tested positive, with a significant difference (P <0.05/OR 1.4) on the overall results. Two of the five evaluated slaughterhouses showed a prevalence decrease of Salmonella spp. in the sampled carcasses after installing the washer. However, in three establishments, there was no significant difference after installing this system. The results suggest that the increase of the water flow is related to the reduction of the contamination, while the increase of the water pressure of the washing system was not enough to reduce the pathogen in the sampled carcasses. The results show operational results since the washing system avoids the trimming of some carcasses, but doesn’t eliminate the risk of Salmonella. Keywords: cross-contamination, control, monitoring, Salmonella
650 _aFRANGO DE CORTE
650 _aABATEDOURO
650 _aCARCAÇA
650 _aSALMONELLA
650 _aCONTAMINAÇÃO
650 _aHIGIENE VETERINÁRIA
650 _aLEGISLAÇAO
773 0 _01643
_9345321
_dBelo Horizonte-MG Universidade Federal de Minas Gerais - Escola de Veterinaria 1983
_o2024-5846
_tArquivo Brasileiro de Medicina Veterinária e Zootecnia (Brazil)
_x0102-0935
_gv, 71(1) p. 250-259; (2071)
_wBR2024002926
856 _uhttps://www.scielo.br/j/abmvz/a/8Hr87fLvx6dV87hZr7cNMdB/?format=pdf&lang=pt
942 _cANA
999 _c328210
_d328210