000 03160nab a2200301 i 4500
003 BR-BrBNA
005 20260320170236.0
008 260320b2017 bl.ar|pooa||| 00| 0 por |
040 _aBR-BrBNA
_bpor
072 _aK50
_b3240
072 _aJ12
100 _aLopes, Dercílio Junior Verly
100 _aPaes, Juarez Benigno
100 _aJankowsky, Ivaldo Pontes
100 _aSegundinho, Pedro Gutemberg de Alcântara
100 _aVidaurre, Graziela Baptista
245 _aInfluências do Diâmetro e Umidade da Madeira na Qualidade do Tratamento Preservativo
500 _aPublicação on-line; 19 ref.; 6 tables; 5 illus.; Summaries (En, Pt)
520 _a RESUMO Avaliaram-se os efeitos do teor de umidade e classe diamétrica na qualidade do tratamento de moirões de Corymbia torelliana e Eucalyptus grandis x Eucalyptus urophylla. Utilizaram-se 108 moirões, sendo 36 tratados e 18 não tratados, com 2,20 m de comprimento e umidade de 15 a 20%; 20 a 30%; 30 a 40%, e diâmetros de 8 a 10 cm; 10 a 12 cm; 12 a 14 cm. No tratamento, foram utilizados 2% de ingredientes ativos de CCA-C, vácuo inicial e final de 550 mmHg (30 min), pressão de 11 kgf cm-2 (1 h). Os moirões tiveram a umidade avaliada pelo medidor elétrico, que foi adequado para estimar a umidade destes. Obtiveram-se penetrações satisfatórias e a maior retenção foi obtida nos moirões com umidade de 15 a 20% (8,23 kg m-3), contudo, umidade de 30 a 40% também foi adequada ao tratamento da madeira, obtendo valores superiores a 6,5 kg m-3. Palavras-chave: tratamento de moirões, arseniato de cobre cromatado, penetração, retenção. Influences of Diameter and Wood Moisture on Quality of the Preservative Treatment ABSTRACT Were evaluated the effects of moisture content and diametric class in industrial treatment quality of Corymbia torelliana and Eucalyptus grandis x Eucalyptus urophylla fence posts. 108 fence posts were used, 36 treated and 18 non-treated, with 2.20m long and moisture content of 15 to 20%; 20 to 30%; and 30 to 40% and diameters of 8 to 10cm; 10 to 12cm; 12 to 14cm. For treatment, were used 2% active ingredients of CCA-C, initial and final vacuum 550 mmHg (30min), pressure of 11 kgf cm-2 (1h). The fence posts were evaluated by electric meter that was adequate to estimate the moisture. Satisfactory penetrations were obtained and the biggest retention was reached in fence posts with moisture of 15 to 20% (8.23 kg m-3), however, the moisture content of 30 to 40% was also suitable for the treatment of wood, getting values higher than 6.5 kg m-3. Keywords: treatment of fence posts, chromium copper arsenate, penetration, retention.
650 _aMOURÃO
650 _aMADEIRA
650 _aTEOR DE UMIDADE
650 _aDIÂMETRO
773 0 _02929
_9347945
_dRio de Janeiro-RJ Instituto de Florestas - UFRRJ 1994
_o2025-0444
_tFloresta e Ambiente (Brazil)
_x1415-0980 / ISSN 2179-8087 0nline
_gv. 24 p. 1-10; (2017)
_wBR2026000259
856 _uhttps://www.scielo.br/j/floram/a/ZhbKYRHDzjmrQSzzPjtWs4D/?format=pdf&lang=pt
942 _cANA
999 _c340494
_d340494